UNI POWER Low Flow Single Button Dispenser Individual (NCL4143)

Price: $170.11
Summary
Economical dispensing solution for a wide variety of products. 1.0 GPM ES-Gap eductors provide back flow prevention with wide regulatory acceptance. Includes foot valve, tubing and assorted tip kit.

** Please note: shipping lead time 3-7 business days

Product Description

Description

An economical way to dispense automatically diluted solutions into spray bottles, buckets or other containers at the touch of a button.  Control dilution accurately for one product.

Code: 4142, 4143
Packaging: Each

Directions

1. Remove cabinet cover. Drill holes for the three wall anchors with a 5/16" drill bit, using the cabinet back as a template for proper spacing of the mounting screws. Install mounting anchors, and then screw in top two anchors. Slide key  holes in cabinet back over screw heads, tighten screws, then install bottom screw. Do not mount more than 6 feet (1.8 meters) above the bottom of the concentrate container, nor below the highest concentrate level (never mount your concentrate higher than the proportioner).

2. Select a metering tip, and insert into hose barb on eductor body. (Repeat for all eductors.)

3. Cut supply tubing, and insert into hose barb on eductor body. (Repeat for all eductors.)

4. Slip other end of supply tube through an opening in either side of the cabinet and push over the hose barb/metering tip on the eductor. (Repeat for all eductors.)

5. Place foot valve ends of supply tubes into concentrate containers.
REMEMBER TO CHECK FOOT VALVES STRAINERS PERIODICALLY FOR CLOGGING. CLEAN IF NECESSARY.

6. A short discharge tube is used with the IGPM eductor; minimum tube length is 8 inches (20cm) for proper operation. Longer tubes (4 feet) are used with a 3.5 GPM eductor. Do not remove the flooding rings from inside the tubes. Slide end of tube with flooding ring over eductor discharge outlet. (Repeat for all eductors) Hooks may be installed on longer tubes to allow discharge tube to conveniently hang from dispenser when not in use.

7. Replace cabinet cover. Push the sides in, behind the latch holes, to snap the cover in place. The two screws provided may be installed in the holes of the cabinet sides to prevent easy removal of cover.

8. Connect water supply hose of at least 3/8" ID to water inlet swivel. (Minimum 25 PSI pressure, with water running, is required for proper operation.) Connect opposite end of hose to water supply. Turn water supply on.

9. Push button to start flow of desired water/concentration solution, and hold until supply tube is primed (filled). Then push the button whenever dispensing is desired. and release button to stop flow of solution.
If you wish to be able to lock the button in the "on" position: clip or bend the two tabs behind the lower front portion of the button. This allows the button to be fully depressed and allows it to latch in the "on" position. To unlock, pull the button out.

Documentation

Miscellaneous Documents Uni-Power Installation Instructions

Product Specs

Specifications

  • Low Flow4143
  • High Flow4142